What is the Solar Building Envelope?
The Solar Building Envelope is a limit on how tall and how close to a boundary your building can be, so that the neighbour keeps their sunlight. It is an imaginary sloping plane. It starts at a 'solar fence' on the northern boundary of the adjoining residential block and slopes up and over your block. Your building must sit wholly inside it.
The solar fence only exists on a neighbour's northern boundary. That is usually the southern boundary of your block, where the neighbour is to your south. Any northern boundary of an adjoining residential block counts.
What the law says (Planning (Residential Zones) Technical Specifications 2026, NI2026-303, specification 15.1, under Assessment Outcome 15)
The solar fence height is:
- Single dwellings on large blocks: 2.4m in the primary building zone and 1.8m on all other parts of the boundary.
- Single dwellings on mid-sized and compact blocks: 3m in the primary building zone and 2.3m on all other parts of the boundary.
- Multi-unit housing (except buildings over 3 storeys in RZ5): 3m in the primary building zone and 2.3m on all other parts of the boundary.
The plane is projected from the top of the solar fence at 31° to the horizontal for single dwellings, and 45° for multi-unit housing. All heights are measured from datum ground level.
The envelope does not apply:
- to a part of a boundary where the neighbouring land is only an access driveway (a 'battle-axe handle');
- to a part of the building that a district technical specification says must be built to the boundary; or
- to compact blocks where a district specification requires a building to be two storeys or more and/or built to the boundary.
The Solar Building Envelope is separate from the Building Envelope. The Building Envelope (specification 14.2) is drawn at 45° from 4m above each side and rear boundary, except where the solar building envelope applies.
How we do it
We check your proposed building against the envelope, and we check the shadows it casts on the neighbour, using shadow diagrams. This is done before the plans are lodged.
CGFB-Q-0308 · last reviewed 24 November 2026