Questions & Answers › Approvals and planning rules
What is a plot ratio and how will it affect my project?
What the planning rules say
Plot ratio is the gross floor area (GFA) of the buildings on a block divided by the area of the block. For example, a building with a GFA of 500 m² on a block of 1,000 m² has a plot ratio of 0.5, or 50%. GFA is the total area of all floors, measured from the external faces of the exterior walls. Structures such as a house, carport, garage and shed count towards it.
Plot ratio is not the same as site coverage. Site coverage is how much of the block is covered by buildings and roofed structures when seen from above. It includes balconies, basements, roofed structures such as carports, pergolas, decks and garden sheds, and cantilevered upper-floor elements. It leaves out eaves and awnings, unroofed decks, terraces and patios, swimming pools, and hard surfaces such as driveways and retaining walls.
The Planning (Residential Zones) Technical Specifications 2026 (NI2026-303) do not set a plot ratio limit. The mandatory limit on how much of a block you can build on is site coverage. It is set in the Residential Zones Policy of the Territory Plan 2023 (NI2023-540), Assessment Requirements 7 and 8. For a single dwelling, or a single dwelling with a Secondary Residence, the maximum site coverage is generally 40% on a large block, 60% on a mid-sized block and 70% on a compact block. For a dual occupancy it is generally 45% in RZ1 and RZ2 and 50% in RZ3, RZ4 and RZ5.
How this affects your project
Site coverage limits how large your extension or Secondary Residence can be. Setbacks, private open space, planting and building height can limit it further. We check these against your block at design stage, so the plan we put to the planning authority fits the rules before the Development Approval is lodged.
CGFB-Q-0826 · last reviewed 24 November 2026