What are urban sensative design rules?
What the law says
Water sensitive urban design for single dwellings is set out in specification 19.5 of the Planning (Residential Zones) Technical Specifications 2026 (NI2026-303), under Assessment Outcome 19. Assessment Outcome 3 also covers water sensitive urban design. NI2026-303 commenced on 1 July 2026 and replaced the 2025 (No 2) specifications.
The specifications are a benchmark for meeting the Territory Plan assessment outcomes. They are not the only way to show compliance. A design that complies with a provision and addresses the assessment outcome does not need further assessment of that provision.
Specification 19.5 applies to all new single dwellings, secondary residences, and extensions and alterations. It does not apply to an extension of a size 50% or less of the existing gross floor area, or to development where no new plumbing is proposed.
Where it applies, the specification sets three options. You need to meet one of them:
Option A: rainwater tank. The requirement depends on block size.
- Compact blocks: no minimum water storage, but WELS rated plumbing fixtures are required.
- Mid-sized blocks: at least 2,000 litres of roof water storage. 50% or 75m2 of roof plan area, whichever is less, is connected to the tank.
- Large blocks up to 800m2: at least 4,000 litres. 50% or 100m2 of roof plan area, whichever is less, is connected to the tank.
- Large blocks 800m2 or greater: at least 5,000 litres. 50% or 125m2 of roof plan area, whichever is less, is connected to the tank.
On mid-sized and large blocks, the tank must be connected to at least a toilet, laundry cold water and the external taps attached to the house. A pump is needed where the connection cannot be raised high enough to give adequate pressure.
Option B: greywater system. The system captures all bathroom and laundry greywater and treats it to Class A standard. The treated water is connected to all laundry cold water, toilet flushing and all external taps.
Option C: prove a 40% saving. You provide evidence that the development uses at least 40% less mains water than an equivalent development built in 2003, using the online assessment tool or another tool. The 40% must be met without relying on landscaping measures. A 40% claim measured any other way does not meet this option.
Development other than single dwellings and secondary residences must instead comply with the ACT Practice Guidelines for Water Sensitive Urban Design Module 2: Designing Successful WSUD Solutions in the ACT (specification 19.6).
How we do it
We check each project against these triggers at the start of design. In our practice, existing floor area is the GFA of all existing structures, and we use that to decide whether an extension is minor.
We rarely pursue Option B. Greywater systems that treat to Class A standard can cost from $10,000 to over $20,000, and a water tank is generally less expensive and less invasive.