Questions & Answers › Who We Are
What are property maintenance access requirements for blocks that contain Icon Water sewerage infrastructure in backyard?
For most developments the requirement ranges between 1.8 - 2.5 metres, with complex cases (2-3% of all developments) assessed on an individual basis.
The maintenance access requirements are dependent on the depth of sewer pipes in backyard
- Pipe Depth < 2.2m Required Maintenance Path width 1.8m; Height Clearance 2.65m.
- Pipe Depth 2.2m-3.0m Required Maintenance Path width 2.5m; Height Clearance 2.85m
- Pipe Depth >3.0m Assessed on an individual basis.
It is found that 61% of the Icon Water network is shallower than 2m deep, 74% is shallower than 2.2m deep, and that 96% of the network is shallower than 3m deep. 97% of backyard pipes are 150mm in size.
QAID 255 · last reviewed 18 November 2026 · also answered on canberragrannyflatbuilders.com.au