In the Icon water (No load zone) diagram, why is that you can build on the no load zone area.
Yes, in some cases. If you use concrete piers, the footings do not put load on the no load zone, so building can be possible there. Building closer than 2m from an easement will need reinforced concrete piers to protect the easement and your project.
You cannot build within the pipe protection envelope. The envelope is the protected space around the pipe. It is not the same thing as the whole easement.
The clearances depend on the nature of the easement and on the size and depth of the pipe. The depth and style of the footings may change as a result. Any work near or over an Icon Water easement must be approved in writing by Icon, and the design must still let Icon get access to its assets.