For upper storey’s what is an acceptable solution when windows are within 6m setback?
Upper-storey windows close to a side or rear boundary are usually made acceptable by stopping them looking straight down into the neighbour's yard or windows. The common ways are a high window sill, fixed obscure (frosted) glass on the lower part of the window, or a fixed external screen. Below we explain each, where the rules come from, and what to check before relying on any figure.
Why it matters
Under the ACT Territory Plan 2023, a new upper floor has to give your neighbours reasonable visual privacy. A window in the upper storey that faces a side or rear boundary and sits within the setback distance is the classic case planners look at. Any floor more than 1.8 m above natural ground level counts as an upper floor level.
The usual acceptable solutions
The Planning (Residential Zones) Technical Specifications set out one way to show the privacy outcome is met. The approaches generally accepted for upper-floor windows near a boundary are:
- A high sill. The bottom of the window is set high above the floor, typically around 1.5 m or more, so you see sky rather than the neighbour's yard.
- Fixed obscure glazing. The window can sit lower, but the glass is frosted or translucent and fixed (non-opening) up to that height above the floor.
- Fixed external screens. Permanent screens such as louvres or battens block the downward view. The size of the gaps between them is limited.
- Moving or reorienting the window. The window is placed on a wall that does not face the neighbour, or angled so it does not look into their private open space or habitable room windows.
The exact heights, screen-gap limits and distances change between versions of the Technical Specifications. Treat the figures above as a guide only and check the current specification before relying on them.
If the design does not follow the technical specification
The technical specifications are not the only way to get approval. In a Development Application you can show the Assessment Outcome for privacy is still met another way, for example because of the site layout, existing screening or where the neighbour's yard sits. The planning authority decides whether that argument is accepted.
An extension that goes straight to a building certifier with no DA has to comply fully with the exemption rules. In practice that means following the rule rather than arguing around it.
Don't forget the building code side
Bedroom windows on an upper floor also have to meet National Construction Code fall-protection rules. These apply where the floor is 2 m or more above the ground below and the window opening is less than 1.7 m above the floor. Usually this means the openable part is restricted or has a screen.
The privacy solution and the fall-protection solution have to work together. For example, obscure glazing that is fixed below the sill line can help with both.
On your project
Your Customer Designer and our planning team assess window placement against these requirements as the design is developed. Window privacy is something we resolve in the plans before they go for approval.
CGFB-Q-0581 · last reviewed 24 November 2026