Does the entire length of the wall need to be fire rated?
Not necessarily. Only the part of the wall that is too close needs to be fire rated.
What the law says
Fire separation is a National Construction Code (NCC) matter. It is assessed as part of Building Approval under the Building Act 2004 (A2004-11).
Boundary: a wall of a Class 1 building that is less than 900mm from a property boundary needs to be fire rated. If the whole wall is under 900mm (for example 850mm), the whole wall needs to be fire rated.
Another building on the same block: fire-resisting construction is generally required where a Class 1 building is less than 1.8m from another building on the same block, such as the existing house. If only a corner is too close (for example 1.6m), only the part of the wall closer than 1.8m needs to be fire rated.
Carports are different. A fire-rated wall is needed where a Class 10a structure such as a carport is less than 900mm from the boundary and less than 900mm from the Class 1 building. The 1.8m distance applies between two Class 1 buildings, not between a carport and a residence.
The NCC gives compliant ways to build a fire-rated wall. These include a wall with a fire resistance level (FRL) of at least 60/60/60, or specified masonry construction. Timber-based materials, windows and doors are not acceptable in a fire-rated wall. Some exceptions apply. If the building is attached to another Class 1 dwelling, extra requirements for the separating wall may apply.
How we do it
We mark the fire-rated part of the wall on your plans with an arrow and the label 'fire rated wall'. A fire-rated wall is an additional cost. Your building certifier confirms the exact requirement for your design, based on the version of the NCC used for your Building Approval.