Does Sarking and Insulation that is installed on the exterior side of the primary insulation layer need to be Vapour Permeable?
Yes. Pliable building membranes (sarking) and any insulation installed on the outside of the primary insulation layer now need to be vapour permeable. That means they let water vapour pass through.
In climate zone 7 (the ACT) they need to be highly permeable. Each must be at least as permeable as a class 4 membrane that complies with AS4200.1. The same applies in climate zones 6 and 8.
The primary insulation layer is the most interior insulation layer of a wall or roof, for example the insulation batts in an external stud wall.
A membrane must also comply with AS4200.1 (Pliable building membranes and layers) and be installed in accordance with AS4200.2.
If no sarking is installed in an external wall, the external cladding is kept apart from water sensitive materials by a drained cavity. This does not apply to single skin masonry, where the brick is both the structural and the external layer.