Questions & Answers › Approvals and planning rules
Does a counter levered carport, where no posts are along side the boundary, be permitted to finish at the boundary?
What the law says
Sometimes. A carport can be built to a side boundary (0m) only where the rules for your block type allow it. The Planning (Residential Zones) Technical Specifications 2026 (NI2026-303) have no separate rule for a cantilevered carport. It is checked against the same setbacks as any other carport (spec 14.4 and Tables 5 to 8).
Large block (Table 5): a garage or carport can be at 0m, on one side boundary only. It must be 3m from the rear boundary.
Mid-sized block in a subdivision approved before 2 October 2009 (Table 6): 0m on Side Boundary 2 only. On Side Boundary 1 it must be 3m. The rear setback is 3m.
Mid-sized block in a subdivision approved on or after 2 October 2009 (Table 7): a district policy or specification decides whether 0m is allowed.
Compact block (Table 8): a garage or carport can be at 0m on both side boundaries. The rear setback is 3m, or 0m only where a district policy or specification specifically permits it.
Where any wall is less than 900mm from a side or rear boundary (spec 14.4(b)):
- No windows are allowed in any part of that wall.
- On a large block, the total length of garage and carport walls facing the boundary is no more than 8m.
- On a mid-sized block, the total length of all walls less than 900mm from a boundary is no more than 13m, and they extend no more than 2.5m into the rear zone.
The notes to 14.4 say carports with posts only are not counted as walls. The specification does not say how a cantilevered roof edge at the boundary is treated, so we confirm this for your design.
The carport must also sit within the building envelope: a 45-degree plane starting 4m above the side and rear boundary (spec 14.2). This does not apply to single dwellings on compact blocks. Where a neighbour is to the south, the solar building envelope (spec 15.1) applies as well.
Planning (Exempt Development) Regulation 2023 (SL2023-21): a carport is a Class 10a building. It can be exempt from a DA if it meets the general exemption criteria (s 1.10) and the conditions in s 1.42. That means it is no more than 4m above datum ground level, behind the building line and within the solar building envelope. Any floor must be no more than 1m above finished ground level. Any part within 1.5m of a side or rear boundary must also keep the combined cross-section of all Class 10 buildings and structures in that 1.5m strip to no more than 30m2 (s 1.41). If it does not meet these, it can still be approved with a DA.
How we do it
We check your block type, subdivision date, any district specification and the cross-section in the 1.5m strip before we confirm the pathway. A carport less than 900mm from the boundary and less than 900mm from the house needs a fire-rated wall. The building certifier confirms the fire separation requirements for your Building Approval under the Building Act 2004.
Tell us your block type and subdivision date and we will confirm which setback applies.
CGFB-Q-0517 · last reviewed 24 November 2026
