Questions & Answers › Approvals and planning rules
Can you legally build an extension unattached or detached from the existing dwelling or home? If so what conditions do you need to meet?
What the law says
Yes. You can build an addition that is not attached to your existing house. There are two ways it can be approved. Which one applies depends on whether the finished building works as a separate home.
If it stays part of your existing house
A detached addition does not need a Development Approval (DA) just because it is detached. Under the Planning (Exempt Development) Regulation 2023 (SL2023-21), section 1.130, work on a single dwelling in a residential zone is exempt from a DA if all of these apply:
- it will be the only dwelling on the block;
- it complies with the Single Dwelling Housing Development Control (the version in force today is NI2025-492) and the relevant district controls;
- you have given the required written information to your adjoining neighbours (s 1.18).
It must also meet the general exemption criteria in section 1.10. These include staying clear of easements and utility access spaces (s 1.11), complying with the heritage, tree and environment laws (s 1.13), not being inconsistent with your lease (s 1.14), not increasing the number of dwellings on the block to two or more (s 1.15), and meeting the mandatory matters control (s 1.17A).
If it meets every rule, it only needs a Building Approval under the Building Act 2004 (A2004-11). If it cannot meet every rule, it needs a DA under the Planning Act 2023 (A2023-18). If the breach is minor, the Territory Planning Authority can make an exemption declaration so the work stays exempt (SL2023-21, ss 1.19B and 1.19C).
If it works as a separate home
It must be approved as a Secondary Residence, and that always needs a DA. A Secondary Residence is a second dwelling on a block that stays subordinate to the main dwelling. Under the Residential Zones Policy in the Territory Plan 2023 (NI2023-540, Part E01):
- it can only be developed in association with single dwelling housing;
- there can be only one per block;
- its maximum dwelling size is 90m², measured to the outside face of the external walls, not counting the garage;
- its maximum is 2 storeys.
Under the Planning (Residential Zones) Technical Specifications 2026 (NI2026-303), it must be at least 40m² (spec 5.1). It also needs at least one parking space in addition to the parking for the main house (spec 27.1(b)). A Secondary Residence cannot be given its own title, by subdivision or by unit titling (NI2023-540, Part F01 Subdivision Policy, requirement 5(a)).
Conditions a DA will test
A detached addition, and a Secondary Residence, are generally assessed against the single dwelling requirements (NI2026-303, spec 4.2). These specifications are a benchmark for meeting the Territory Plan's assessment outcomes. They are not the only way to meet them. The main conditions are below. If you are using the exempt route, the Single Dwelling Housing Development Control has its own figures, so check that control for your block.
- Site coverage: a maximum of 40% of the block on large blocks, 60% on mid-sized blocks and 70% on compact blocks. This includes all roofed Class 10 buildings (NI2023-540, Residential Zones Policy, Assessment Requirement 7).
- Building envelope: the building must sit inside planes projected at 45° from 4m above each side and rear boundary (spec 14.2). This does not apply to single dwellings on compact blocks, and it does not apply on boundaries where the solar building envelope applies.
- Front, side and rear setbacks: these depend on your block size and when the estate was approved (specs 14.3 and 14.4, Tables 1 to 8).
- Solar building envelope: the building must sit inside a plane at 31° for single dwellings, measured from the 'solar fence' height on a northern boundary of the neighbouring block (spec 15.1).
- Neighbours' sunlight: a daytime living space and 50% of the minimum principal private open space on the neighbouring block must keep at least 3 hours of direct sun between 9am and 3pm on 21 June. Where they already get less, the sun they get must not be reduced further. Existing rooftop solar panels and solar hot water must keep at least 4 hours (spec 15.3 to 15.5).
- Water saving: this applies only where the extension is bigger than 50% of the existing gross floor area and adds new plumbing. It does not apply to an extension of 50% or less, or where no new plumbing is proposed (spec 19.5).
How we do it
We check early whether your design would be treated as a separate dwelling. We usually install the kitchen after the Certificate of Occupancy and Use has been issued. This avoids the extension being held up in planning over whether it counts as a separate dwelling. This is why detached additions we build often do not include their own kitchens and laundries. If you want a kitchen in the addition, tell us at the start. We will tell you whether it can stay an extension or has to be approved as a Secondary Residence.
CGFB-Q-0268 · last reviewed 24 November 2026