What the planning rules say
Sometimes. It depends on which boundary it is and on your block type. The Planning (Residential Zones) Technical Specifications 2026 (NI2026-303) set carport setbacks in Tables 1 to 3 (front) and Tables 5 to 8 (side and rear), under specifications 14.3 and 14.4.
Side and rear boundaries
Large block (Table 5): a carport can be on a side boundary (0m) on one boundary only. It must be 3m from the rear boundary.
Mid-sized block in a subdivision approved before 2 October 2009 (Table 6): a carport can be at 0m on Side Boundary 2 only. It must be 3m from Side Boundary 1 and 3m from the rear boundary.
Compact block (Table 8): a carport can be at 0m on both side boundaries. The rear boundary is 3m, or 0m only where a district policy or specification specifically permits it.
For mid-sized blocks approved on or after 2 October 2009 (Table 7), a district policy or specification decides whether 0m is allowed.
Where any wall is less than 900mm from a side or rear boundary (specification 14.4(b)):
- No windows are allowed in any part of that wall.
- On a large block, the total length of garage and carport walls facing the boundary is no more than 8m.
- On a mid-sized block, the total length of all walls less than 900mm from a boundary is no more than 13m. They can extend no more than 2.5m into the rear zone.
Carports with posts only are not counted as walls.
Front boundary
A carport has a larger front setback than a dwelling. For the primary frontage it is 6m in Table 1, and 5.5m in Tables 2 and 3, with at least 1.5m behind the front building line. Table 3 does not require the 1.5m where there is a courtyard wall in the front zone.
A carport cannot be in the front zone (specification 27.3(a)). The exceptions are a compact block, and any part of a driveway in tandem with another car space that is behind the front building line. The front zone is the area between the front boundary and the building line, or the minimum front setback of the lower floor level, whichever is greater. It is never more than 10m from the front boundary.
Whether you need a development application (DA)
The Planning (Exempt Development) Regulation 2023 (SL2023-21) decides this. A carport is a Class 10a building. It does not need a DA if it meets section 1.42 and section 1.41, and the general criteria in section 1.10:
- It is no more than 4m above datum ground level.
- It is wholly inside the solar building envelope.
- It is behind the building line.
- Any floor is no more than 1m above finished ground level.
- Within 1.5m of a side or rear boundary, all Class 10 buildings and structures together have a cross-section area of no more than 30m2 (section 1.41).
- It does not conflict with easements or service clearances, heritage or tree laws, or your lease (sections 1.11, 1.13 and 1.14).
A carport forward of the building line is not covered by section 1.42, so it needs a DA. A carport that does not meet the limits above can still be approved with a DA. The project may also need building approval.
How we handle it
We check your block type, subdivision date, setbacks and any district specification before we confirm the pathway. Any wall less than 900mm from the boundary and less than 900mm from the house needs to be fire rated (FRL 60/60/60 in the ACT). Our planning approvals manager confirms which pathway applies to your carport.