Questions & Answers › Approvals and planning rules
Are 2.4 m ceiling allowable in Bedrooms or living areas?
What the law says
It depends on the type of development. Under the Planning (Residential Zones) Technical Specifications 2026 (NI2026-303), specification 17.6, these are the minimum ceiling heights for multi-unit housing:
• A habitable room, such as a bedroom or living area, is a minimum of 2.7m.
• A non-habitable room or kitchen is a minimum of 2.4m.
• The upper level of a 2 storey apartment is a minimum of 2.4m, where the upper level area is less than 50% of the floor.
So a 2.4m ceiling in a bedroom or living area is below the specification, apart from that upper-level case.
A dual occupancy has 2 dwellings, so under specification 4.2 it follows the multi-unit housing requirements, including 17.6. Specification 17.6 is written for multi-unit housing. NI2026-303 sets no ceiling height for a single dwelling or a Secondary Residence.
The technical specifications are a benchmark, not a hard rule. Falling short of one does not automatically mean refusal. You can put forward a different design and show how it still meets the Assessment Outcome. The relevant outcome here is Assessment Outcome 17: dwellings in multi-unit housing must ‘provide for a comfortable living environment that meets the changing needs of residents’. Assessment Outcomes must be met. A mandatory Assessment Requirement in the Territory Plan (NI2023-540) cannot be departed from.
How we approach it
The Planning Team at CGFB believes the Territory Planning Authority would be likely to accept 2.4m ceilings in a dual occupancy if the design response shows the dwellings are still comfortable to live in. This is our view and not a guarantee, and the Authority makes the decision on each application.
CGFB-Q-0752 · last reviewed 24 November 2026